Physiological signal processing
Blood pressure waveform modelling with NABNet
How accurately can arterial pressure waveforms and their pressure components be estimated from synchronized PPG and ECG?
Biomedical Signal Processing and Control ยท 2023
Approach
The nested attention-guided BiConvLSTM reconstructs an arterial blood pressure waveform from photoplethysmography and electrocardiography. A component estimation stage supplies pressure values used to recover the waveform scale.
Reported results
Table 5 reports the following mean absolute errors for the combined waveform and pressure estimation pipeline on the UCI waveform benchmark.
- Systolic pressure error
- 2.63 mmHg
- Diastolic pressure error
- 1.09 mmHg
- Mean arterial pressure error
- 2.37 mmHg
My contribution
I led data preparation, implementation, experiments, analysis, visualization, and manuscript preparation.
Study scope
These errors come from retrospective evaluation on intensive-care waveform records. The partition kept records from the same patient together.