All research

Physiological signal processing

Blood pressure waveform modelling with NABNet

How accurately can arterial pressure waveforms and their pressure components be estimated from synchronized PPG and ECG?

Biomedical Signal Processing and Control ยท 2023

Approach

The nested attention-guided BiConvLSTM reconstructs an arterial blood pressure waveform from photoplethysmography and electrocardiography. A component estimation stage supplies pressure values used to recover the waveform scale.

Reported results

Table 5 reports the following mean absolute errors for the combined waveform and pressure estimation pipeline on the UCI waveform benchmark.

Systolic pressure error
2.63 mmHg
Diastolic pressure error
1.09 mmHg
Mean arterial pressure error
2.37 mmHg

My contribution

I led data preparation, implementation, experiments, analysis, visualization, and manuscript preparation.

Study scope

These errors come from retrospective evaluation on intensive-care waveform records. The partition kept records from the same patient together.